Study the ability of using anode based on silicon iron alloy in cathodic protection by impressed current for carbon steel in soil

Authors

  • Đinh Thị Mai Thanh
  • Nguyễn Văn Chiến
  • Nguyện Thị Linh

Abstract

Four specimen on basis silicon iron CTT, TTCU, TTU, TTU-V was test corrosion in the soil by mesure rest potential, polarisation potential and electrochemical impedance methods. The rest potential of specimen in the soil increase  (CTToC, the potential  attain -0,53 V/Cu, CuSO4 after 2300 second  testing  for TTU-V specimen. The density current value of CTT and TTCU specimen is about 10-6 A/cm2 to meet requirements for using inert anode in cathodic protection by impressed current. The density current increase about ten times for TTU-V and TTU because of there  are FeVO4 forming on the TTU-V anode and Fe2O3 on  TTU anode. The result of impedance measure shown that the Rct resistance relatively accord with Rp resistance obtains by polarization potential method.

Downloads

Download data is not yet available.

Published

2014-11-20